Research Article

Experimental Study on Lateral Resolution of Phased Array Ultrasonic Testing of Irregular Structure Weld Defects

Table 4

Comparison of fixed length of defects between horizontal through holes 1 and 2.

C ScanningSimulationTest

−6 dBNO.1NO.2NO.1NO.2
Defect fixed length9.09 mm8.85 mm9.21 mm9.02 mm