Research Article
Three-Level SOC Equalization Control Strategy for MMC-BESS Based on Feedforward Sliding Window Integral Method
Table 4
Capacitor voltage distortion rate of c-phase submodule using one-third average method and sliding window integral method.
| Harmonic distortion rate of capacitor voltage of submodule |
| One-third average method: | | 5 s | 5.2 s | 5.4 s | 5.6 s | 5.8 s | Upper bridge arm of phase C (sm1 ∼ sm4) | 13.18% | 13.95% | 13.94% | 15.81% | 14.34% | Lower bridge arm of phase C (sm5 ∼ sm8) | 12.51% | 13.76% | 13.35% | 14.72% | 13.34% |
| Sliding window integral method: | | 5 s | 5.2 s | 5.4 s | 5.6 s | 5.8 s | Upper bridge arm of phase C (sm1 ∼ sm4) | 13.07% | 13.39% | 13.49% | 13.62% | 14.01% | Lower bridge arm of phase C (sm5 ∼ sm8) | 12.26% | 12.80% | 13.24% | 12.81% | 13.26% |
|
|