Research Article

A Fluid-Structure Interaction Model for Bridge Safety Assessment under Scour Conditions

Table 3

Frequency comparison between governing variables experiment and simulation.

Embedded depth (cm)865

Freq. (experiment)10.7610.4110.21
Freq. (simulation)10.7710.079.70
Error0.1%3.2%5.0%