Seismic Performance of Concrete-Filled Square Steel Tubular Column-Steel Beam Sleeve Joint

Table 3

Failure phenomena of specimens.

No.Vertical loading displacementFailure phenomena

CFST-155 mm (1)The upper flange of the right beam and the lower flange of the left beam have large local buckling
55 mm (2)The sleeve local buckling at the connection between the right beam and the sleeve and the left beam and the sleeve is about 15 mm and 20 mm, respectively
55 mm (3)The upper flange weld of the right beam and the lower flange weld of the left beam crack
60 mm (1)The base metals on the lower side of the right beam and the upper side of the left beam are torn
60 mm (3)The base metals on the upper and lower flanges are torn
65 mm (2)The connection between the sleeve and the upper flange and the sleeve and the lower flange of the right beam is torn about 30 mm and 8 mm, respectively; the connection between the sleeve and the upper flange of the left beam is torn about 40 mm
65 mm (3)The specimen failure occurs
CFST-255 mm (1)The adhesion failure occurs between the concrete and steel tube wall
60 mm (1)The base metal on the lower flange of the right beam is torn
60 mm (2)The base metal on the upper flange of the left beam is torn, and the sleeve local buckling occurs
65 mm (1)The sleeve of the right beam has a tear of about 2 mm
65 mm (2)The upper flange of the left beam is partially separated from the sleeve
65 mm (3)The flange on both sides of the beam is separated from the sleeve, and specimen failure occurs
CFST-365 mm (1)The upper flange of the right beam has a local buckling
65 mm (2)The sleeve of the left beam has a local buckling of about 8 mm
65 mm (3)The base metals on the lower side of the right beam and the upper side of the left beam are torn, and the sleeve of the left beam has a local buckling of about 12 mm
70 mm (1)The left beam is distorted
70 mm (2)The base metal has been torn, and the sleeve of the left beam has a crack of about 6 mm
70 mm (3)The sleeve of the left beam is slightly damaged and has a local buckling, and the whole weld is torn
75 mm (2)The flange on both sides of the beam is separated from the sleeve, and specimen failure occurs