Research Article

A Modified Transfer Matrix Method for Modal Analysis of Stepped Rotor Assembly Applied in the Turbomolecular Pump

Table 2

The natural frequencies of the stepped shaft.

Traditional TMM (Hz)FEM (Hz)Error (%)

1st order bending frequency243.97226.017.95
2nd order bending frequency411.64387.886.13