Research Article

A Modified Transfer Matrix Method for Modal Analysis of Stepped Rotor Assembly Applied in the Turbomolecular Pump

Table 3

The results of the rotor modal by the modified TMM and FEM.

Modified TMM (Hz)FEM (Hz)Error (%)

1st order bending frequency2837.12840āˆ’0.102