Research Article

Application of Viscoelastic Tuned Mass Dampers in Vibration Mitigation of Steel Joist Jack Arch Floor Structures

Table 2

Peak response acceleration of the jack arch floor structure under different walk-in-place load models.

ModelLoad frequency (Hz)Peak response acceleration (%g)

Blanchard et al. [29]1.5
2.0
3.0
0.086
0.029
0.076
Bachmann and Ammann [30]1.5
2.0
3.0
N/A
0.142
N/A
Kerr [31]1.5
2.0
3.0
0.060
0.091
0.388
Young [32]1.5
2.0
3.0
0.078
0.074
N/A
Chen [33]1.5
2.0
3.0
0.110
0.147
0.340

Not applicable as the loading frequency is beyond the valid range of the model.