Research Article

A Fault Identification Method for Electric Submersible Pumps Based on DAE-SVM

Table 7

.Accuracy rates and evaluation index corresponding to different data.

 Accuracy (%)MAERMSEMAPER2

Overall97.610.02700.02560.139196.87
Condition 193.110.02890.03200.155995.33
Condition 296.810.03060.05430.247496.71
Condition 395.010.04570.04610.133994.33
Condition 494.190.03630.02310.357997.34