Test results of rubber concrete under freeze-thaw cycle.
| Number | Average strain rate (s−1) | Specimen height (mm) | Diameter (mm) | Dynamic compressive strength (MPa) | Dynamic ultimate strain (10−3) | Static average strength (MPa) | DIF | Absorption energy (J) |
| XJ-0-0.3 | 72.3 | 36.98 | 74.12 | 37.5 | 19.8 | 31.5 | 1.19 | 24.7 | XJ-0-0.4 | 96.7 | 37.02 | 73.56 | 45.7 | 21.6 | 1.45 | 33.8 | XJ-0-0.5 | 124.6 | 36.38 | 73.98 | 57.3 | 23.3 | 1.82 | 49.7 | XJ-0-0.6 | 151.7 | 37.72 | 74.00 | 70.6 | 24.1 | 2.24 | 61.6 |
| XJ-25-0.3 | 78.1 | 37.78 | 73.78 | 31.2 | 21.5 | 25.8 | 1.21 | 19.5 | XJ-25-0.4 | 99.6 | 37.01 | 73.78 | 36.4 | 22.5 | 1.41 | 28.4 | XJ-25-0.5 | 127.1 | 36.02 | 73.97 | 44.1 | 24.1 | 1.71 | 40.6 | XJ-25-0.6 | 155.4 | 37.18 | 73.89 | 52.9 | 24.6 | 2.05 | 53.5 |
| XJ-50-0.3 | 74.6 | 36.78 | 74.34 | 25.8 | 22.1 | 22.4 | 1.15 | 18.6 | XJ-50-0.4 | 102.6 | 37.16 | 74.21 | 31.6 | 23.1 | 1.41 | 26.7 | XJ-50-0.5 | 128.7 | 37.32 | 73.42 | 36.3 | 24.8 | 1.62 | 37.8 | XJ-50-0.6 | 156.3 | 37.67 | 74.22 | 44.4 | 25.7 | 1.98 | 52.1 |
| XJ-75-0.3 | 77.4 | 36.76 | 73.98 | 24.2 | 22.6 | 20.7 | 1.17 | 16.7 | XJ-75-0.4 | 99.2 | 36.59 | 73.78 | 27.9 | 23.9 | 1.35 | 28.3 | XJ-75-0.5 | 130.9 | 37.18 | 74.57 | 34.0 | 25.5 | 1.64 | 33.8 | XJ-75-0.6 | 154.3 | 37.38 | 74.25 | 38.1 | 26.7 | 1.84 | 49.3 |
| XJ-100-0.3 | 73.2 | 37.25 | 74.06 | 22.3 | 22.5 | 18.6 | 1.20 | 14.1 | XJ-100-0.4 | 95.6 | 36.87 | 74.10 | 25.7 | 24.8 | 1.38 | 23.6 | XJ-100-0.5 | 133.5 | 36.77 | 74.02 | 29.8 | 26.1 | 1.60 | 29.5 | XJ-100-0.6 | 158.2 | 36.85 | 74.06 | 33.5 | 27.5 | 1.80 | 40.2 |
| XJ-125-0.3 | 74.4 | 37.08 | 73.95 | 21.7 | 23.3 | 17.9 | 1.21 | 15.3 | XJ-125-0.4 | 98.2 | 37.42 | 73.92 | 27.4 | 25.5 | 1.53 | 25.1 | XJ-125-0.5 | 129.6 | 37.30 | 74.11 | 29.2 | 26.7 | 1.63 | 28.9 | XJ-125-0.6 | 157.7 | 37.05 | 74.15 | 31.9 | 27.9 | 1.78 | 35.7 |
|
|
Note. XJ-0-0.3 in XJ means rubber concrete, 0 means the number of freeze-thaw cycles is 0, 0.3 means the air pressure is 0.3 MPa.
|