Research Article
Efficacy of the Combined Use of Bed Sill and Sacrificial Piles to Control Local Scour around Circular Bridge Piers
Table 1
A summary of the results of the combined countermeasures.
| | Researchers | Combined countermeasures | (%) |
| | Gaudio et al. [13] | Submerged vanes | 12.4 | | Bed sill | 17.2 | | Sacrificial piles | 32.2 | | Collar | 28.7 | | Slot | 33.2 | | Submerged vanes and bed sill | 25.3 | | Sacrificial piles and collar | 36.2 | | Sacrificial piles and slot | 38.1 | | Slot and collar | 81.8 | | Bed sill and collar | 46.2 |
| | Chiew [14] | Slot | 20 | | Collar | 20 | | Slot and collar | 100 |
| | Grimaldi et al. [10] | Slot | 30 | | Bed sill | 26 | | Slot and bed sill | 45 |
| | Soltani-Gerdefaramarzi et al. [15] | Jet injection | 30 | | Bed suction | 9 | | Jet injection and bed suction | 50.4 |
| | Moncada-M et al. [16] | Collar | 55 to 96 | | Slot | 60 to 88 | | Collar and slot | 100 |
| | Mashahir et al. [17] | Collar | 23 | | Collar and bars | 27 |
| | Shahkarami [18] | Bed sill | 20 | | Collar | 65 | | Bed sill and collar | 75 |
| | Mazloom et al. [19] | Slot | 25 | | Submerged vanes | 35 | | Slot and submerged vanes | 86 |
| | Zomorodian et al. [20] | Sacrificial piles | 46.67 | | Collar | 70 | | Slot | 31 | | Sacrificial piles and collar | 75 | | Sacrificial piles and slot | 63 | | Slot and collar | 73 |
| | Aghli and Zomorodian [21] | Cable | 59 | | Collar | 55 | | Cable and collar | 69.7 |
| | Shojaei et al. [22] | Submerged vanes | 2 | | Collar | 35 | | Submerged vanes and collar | 61 |
| | Izadinia and Heidarpour [7] | Cable | 12.85 | | Collar | 28.57 | | Cable and collar | 52.85 |
| | Tafarojnoruz et al. [23] | Collar | 28.7 | | Collar and bed sill | 64.5 |
| | Javidi-Vahdati et al. [24] | Sacrificial piles | 55 | | Sacrificial piles and cable | 60 |
| | Gerami et al. [25] | Bed sill | 25.4 | | Cable | 13.4 | | Bed sill and cable | 34.4 |
|
|