Research Article

A Bursting Liability Evaluation Method Based on Energy Transfer

Table 5

Validation results of the energy transfer index.

Coal seamKEWETPoisson’s ratioΩ resultStandard result

M232.56922.5460.3310.647 strongStrong
M3-11.73113.5380.3420.251 weak
M3-23.22413.0030.3180.451 weak
M4-31.59010.3390.2960.215 weak
M69.13719.7430.2830.621 strongStrong
Z214.53518.4330.3510.503 strong
Z223.80720.5680.3120.494 weak
Z233.06524.6480.2920.459 weak
Z62.40421.9610.3040.388 weak
Z72.57521.1470.3100.405 weakWeak
Y12.85318.7720.3060.432 weakWeak
Y2126.66920.3410.2940.667 strongStrong
Y223.93128.9090.3160.500 strong
Y2315.32521.9910.2630.668 strongStrong
Y142.99914.1800.2860.450 weak
Y153.29531.9540.3450.453 weak