Research Article

Some Insights into Analytical Bias Involved in the Application of Grab Sampling for Volatile Organic Compounds: A Case Study against Used Tedlar Bags

Table 4

Correlation analysis between individual components and the reference parameters (D/T and TVOC).
(a) Polar compounds

AAATMAADATANBTDCEACEAIAMBMEKPTPHTHF

D/T 𝑟 −0.12−0.16−0.08−0.01 8 . 9 3 𝐸 0 5 0.1 3 . 0 2 𝐸 0 3 −0.05−0.06−0.12−0.05−0.020.07−0.16−0.05
𝑃 0.560.450.680.9610.620.990.820.760.580.820.920.750.450.79
TVOC 𝑟 0.410.63−0.25−0.08−0.01−0.05−0.040.970.510.52−0.060.93−0.040.56−0.24
𝑃 0.04* 6 . 0 2 𝐸 0 4 ** 0.220.690.950.830.85 1 . 1 5 𝐸 1 5 ** 0.010.010.78 9 . 6 2 𝐸 1 2 ** 0.84 2 . 8 6 𝐸 0 3 0.24

(b) Nonpolar compounds

D/TTVOCBCOSDOEBIBMADDOTpXT

D/T 𝑟 1−0.06−0.070.130.18−0.13−0.16−0.07−0.10−0.09−0.10−0.09
𝑃 0.760.720.510.370.510.430.720.630.650.630.68
TVOC 𝑟 −0.061−0.160.510.12−0.10−0.18−0.170.090.09−0.050.79
𝑃 0.76 0.430.01**0.560.630.390.400.650.650.82 1 . 4 3 𝐸 0 6 **

*Probability of no correlation less than 0.05.
**Probability of no correlation less than 0.01.