Research Article
The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation
Table 5
Maximum responses of the conductor.
|
Seismic wave |
Peak acceleration (m/s2) | Tension force (kN) | Vertical displacement (m) | Without considering strain rate | Considering strain rate | Without considering strain rate | Considering strain rate |
| El Centro | 6.0 | 21.262 | 21.263 | 8.859 | 8.872 | 8.0 | 21.244 | 21.245 | 8.625 | 8.635 | 10.0 | 21.224 | 21.134 | 8.423 | 8.419 | 12.0 | 22.089 | 22.205 | 8.420 | 8.408 | 14.0 | 21.185 | 21.310 | 8.184 | 8.184 | 15.0 | Collapse | 21.651 | Collapse | 8.197 | 16.0 | Collapse | Collapse | Collapse | Collapse |
| Kobe | 6.0 | 21.321 | 21.321 | 8.629 | 8.629 | 8.0 | 21.322 | 21.322 | 8.640 | 8.639 | 10.0 | 21.322 | 21.323 | 8.674 | 8.674 | 12.0 | 21.324 | 21.323 | 8.707 | 8.706 | 13.0 | 21.361 | 21.359 | 8.756 | 8.758 | 14.0 | Collapse | 21.366 | Collapse | 8.790 | 15.0 | Collapse | Collapse | Collapse | Collapse |
| Northbridge | 10.0 | 21.323 | 21.323 | 8.377 | 8.377 | 15.0 | 21.324 | 21.324 | 8.081 | 8.081 | 20.0 | 22.239 | 22.219 | 7.386 | 7.389 | 23.0 | 21.326 | 21.346 | 7.219 | 7.217 | 25.0 | 21.545 | 21.517 | 7.220 | 7.220 | 27.0 | 21.617 | 21.424 | 7.221 | 7.215 | 29.0 | Collapse | 22.203 | Collapse | 7.223 | 30.0 | Collapse | Collapse | Collapse | Collapse |
|
|