Research Article

Integrating a Hive Triangle Pattern with Subpixel Analysis for Noncontact Measurement of Structural Dynamic Response by Using a Novel Image Processing Scheme

Table 1

The comparison of numerical simulation result.

Simulation
case
BlockaExecution time (s)RMSE

Previous study [12]164 × 280_30 × 30260.595849723
251 × 271_57 × 49810.571394047
355 × 275_49 × 42640.590442405
451 × 271_205 × 10490.572254826
5160 × 120_120 × 30760.726009534
670 × 50_205 × 10460.68851133

This work751 × 271_57 × 49160.554749224
851 × 271_205 × 10130.550491283

The datum denotes (Left) × (Top)_(Width) × (Height).