Research Article

Model Updating of Complex Structures Using the Combination of Component Mode Synthesis and Kriging Predictor

Table 1

Comparison of dynamic properties between condensed and uncondensed FEM.

ModeFrequency (Hz)Frequency error (%)MAC*
Condensed FE modelUncondensed FE model

16.916.880.440.91
27.137.120.140.90
311.0010.960.370.92
416.9316.910.120.90
517.2017.190.060.92
620.5420.600.290.93

MAC represents the modal assurance criterion.