Research Article
A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete
| Specimen ID: AC-4 with = 57 mV; = 948 Ohm | (Ohm) | (mV) | | |
| 1000 | 11.9 | 0.0010 | 0.08 | 1500 | 13.6 | 0.0007 | 0.07 | 2000 | 15.0 | 0.0005 | 0.07 | 2500 | 16.2 | 0.0004 | 0.06 | 3000 | 17.1 | 0.0003 | 0.06 | 3500 | 17.8 | 0.0003 | 0.06 | 4000 | 18.4 | 0.0003 | 0.05 | 4500 | 19.0 | 0.0002 | 0.05 | 5000 | 19.4 | 0.0002 | 0.05 | 5500 | 19.8 | 0.0002 | 0.05 |
|
|