Research Article

A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete

Table 1

Sample calculation for .

Specimen ID: AC-4 with = 57 mV; = 948 Ohm
(Ohm) (mV)

100011.90.00100.08
150013.60.00070.07
200015.00.00050.07
250016.20.00040.06
300017.10.00030.06
350017.80.00030.06
400018.40.00030.05
450019.00.00020.05
500019.40.00020.05
550019.80.00020.05