Research Article

Research on the Compression Algorithm of the Infrared Thermal Image Sequence Based on Differential Evolution and Double Exponential Decay Model

Table 3

Effect of evaluation parameter values of 500-frame thermal image data fitted by model with or without constant term.

Evaluation parametersInitial model (w/o constant term)Improved model (w constant term)

SSE35.270.89
-square0.99070.9998
Adjusted -square0.98150.9995
RMSE0.26560.0422