Research Article
Biomechanical Behavior of Bioactive Material in Dental Implant: A Three-Dimensional Finite Element Analysis
Table 4
Strain in the implant system in three different pitch designs of implant and three materials.
| Pitch types | Material | Strain | Load applied | 100 N | 150 N | 200 N | 250 N |
| Pitch 1 (1 mm) | Titanium | 0.000160 | 0.000240 | 0.000321 | 0.000401 | Reduced graphene oxide (RGo) | 0.000162 | 0.000247 | 0.000330 | 0.000413 | Graphene | 0.000170 | 0.000255 | 0.000340 | 0.000425 |
| Pitch 2 (1.4 mm) | Titanium | 0.000162 | 0.000246 | 0.000328 | 0.000411 | Reduced graphene oxide (RGo) | 0.000172 | 0.000259 | 0.000345 | 0.000431 | Graphene | 0.000178 | 0.000267 | 0.000356 | 0.000445 |
| Pitch 3 (2.2 mm) | Titanium | 0.000154 | 0.000231 | 0.000308 | 0.000385 | Reduced graphene oxide (RGo) | 0.000161 | 0.000242 | 0.000323 | 0.000404 | Graphene | 0.000174 | 0.000262 | 0.000349 | 0.000436 |
|
|