Research Article
Biomechanical Behavior of Bioactive Material in Dental Implant: A Three-Dimensional Finite Element Analysis
Table 5
Deformation in the implant system in three different pitch designs of implant and three materials.
| Pitch types | Material | Load applied | 100 N | 150 N | 200 N | 250 N |
| Pitch 1 (1 mm) | Titanium | 0.007 | 0.0010 | 0.0014 | 0.0017 | Reduced graphene oxide (RGo) | 0.0006 | 0.0010 | 0.0013 | 0.0017 | Graphene | 0.0006 | 0.0009 | 0.0013 | 0.0016 |
| Pitch 2 (1.4 mm) | Titanium | 0.00069 | 0.001 | 0.0013 | 0.0017 | Reduced graphene oxide (RGo) | 0.00067 | 0.0010 | 0.0013 | 0.0017 | Graphene | 0.00066 | 0.0009 | 0.0013 | 0.0016 |
| Pitch 3 (2.2 mm) | Titanium | 0.0007 | 0.0010 | 0.0013 | 0.0017 | Reduced graphene oxide (RGo) | 0.0006 | 0.0009 | 0.0013 | 0.0016 | Graphene | 0.0006 | 0.0010 | 0.0013 | 0.0016 |
|
|