Research Article

On Criticality for a Generalized Couette Flow of a Branch-Chain Thermal Reactive Third-Grade Fluid with Reynold’s Viscosity Model

Table 1

Comparison of results for the method of weighted residual collocation and numerical scheme.

(weighted residual results) (numerical results)Absolute error

−1.0000
−0.80.20040370970.2004037157
−0.60.39014066120.3901406655
−0.40.56635656690.5663565721
−0.20.72570247190.7257024783
0.00.86397550220.8639755148
0.20.97546484750.9754648530
0.41.05182619841.0518262021
0.61.08192968711.0819296900
0.81.06103311961.0610331246
1.01.00000000001.00000000000