Research Article
On Criticality for a Generalized Couette Flow of a Branch-Chain Thermal Reactive Third-Grade Fluid with Reynold’s Viscosity Model
Table 1
Comparison of results for the method of weighted residual collocation and numerical scheme.
| | (weighted residual results) | (numerical results) | Absolute error |
| −1.0 | 0 | 0 | 0 | −0.8 | 0.2004037097 | 0.2004037157 | | −0.6 | 0.3901406612 | 0.3901406655 | | −0.4 | 0.5663565669 | 0.5663565721 | | −0.2 | 0.7257024719 | 0.7257024783 | | 0.0 | 0.8639755022 | 0.8639755148 | | 0.2 | 0.9754648475 | 0.9754648530 | | 0.4 | 1.0518261984 | 1.0518262021 | | 0.6 | 1.0819296871 | 1.0819296900 | | 0.8 | 1.0610331196 | 1.0610331246 | | 1.0 | 1.0000000000 | 1.0000000000 | 0 |
|
|