Research Article

Applying Robust Intelligent Algorithm and Internet of Things to Global Maximum Power Point Tracking of Solar Photovoltaic Systems

Table 2

Output voltage drop under step load.

Classical TSMCProposed algorithm

Step loadsNo load to full loadNo load to full load
Voltage drop60.2 Vmax10.2 Vmax
Improvement degreeNearly eighty-four percent improvement in voltage drop reduction