Research Article

Research and Design of Distributed IoT Water Environment Monitoring System Based on LoRa

Table 2

Node monitoring results on November 8, 2019 (clear weather).

Monitoring timeWater quality parameterStandard valueNode actual valueRelative error (%)

00 : 00Water temperature (°C)17.8517.83-0.11
pH8.318.320.12
Conductivity (mS/cm)0.340.33-2.94
Turbidity (NTU)26.526.4-0.38

08 : 00Water temperature (°C)18.9018.94+0.21
pH7.887.86-0.25
Conductivity (mS/cm)0.350.36+2.86
Turbidity (NTU)26.626.60

16 : 00Water temperature (°C)18.7818.81+0.15
pH8.338.41+0.96
Conductivity (mS/cm)0.330.35+6.06
Turbidity (NTU)26.927.1+0.74