Research Article

Flow-Through Portable Antivirus UV-C Optical Enclosures to be Used with Protective Masks

Table 2

Comparison of optical simulations with the measurements.

Distance (mm)Irradiance “measured” (μW/cm2)Irradiance “optical simulation” (μW/cm2)Difference (%)

100128.0127.40.5
15059.059.10.2
20034.034.00.0
30015.515.21.9