SVM comprehensive test results.

Kernel functionMotor statusNumber of test samplesNumber of correct classificationsNumber of misclassificationsCorrect rateTotal correct rate

LinearNormal2523292%90.67%
Uniform demagnetization2524196%
Partial demagnetization2521484%

PolynomialNormal2523292%89.33%
Uniform demagnetization2524196%
Partial demagnetization2520580%

Radial basisNormal2523292%88%
Uniform demagnetization2524196%
Partial demagnetization2519686%