LSSVM comprehensive test results.

Kernel functionMotor statusNumber of test samplesNumber of correct classificationsNumber of misclassificationsCorrect rateTotal correct rate

LinearNormal2524196%98.67%
Uniform demagnetization25250100%
Partial demagnetization25250100%

PolynomialNormal2523292%92%
Uniform demagnetization2524196%
Partial demagnetization2522388%

Radial basisNormal25250100%94.67%
Uniform demagnetization2523292%
Partial demagnetization2523292%