Recorded parameters of the fuel stack at diverse functioning temperature conditions.

Category of controllerCurrent of FS (A)Voltage of FS (V)Power of FS (W)DC-DC current (A)DC-DC voltage (V)DC-DC power (W)Efficiency (%)Time of settling (sec)Distortions

The functioning temperature of the fuel stack (303 K)
EIC-FLC104.2036.143765.787.524498.213585.77595.220.042High
IHC-FLC104.8936.923872.537.612498.353711.4395.840.038High
AB-FLC105.0537.273915.217.699498.873797.3696.990.032Medium
EDE-FLC105.3237.353933.707.750499.123820.4097.120.028Medium
MPO-FLC105.7637.423957.537.831499.513858.5997.500.025Low
AGA-ANFIS106.2237.884023.617.851499.953931.4697.710.021Low

The functioning temperature of the fuel stack (323 K)
EIC-FLC109.9237.844159.378.12499.164047.89897.320.032High
IHC-FLC110.4437.894184.578.92500.514076.1897.410.031High
AB-FLC111.5238.914339.248.95501.234229.8997.480.029Medium
EDE-FLC112.1739.224399.308.98501.324320.5598.210.024Medium
MPO-FLC112.3340.054498.818.99501.884418.7398.220.022Low
AGA-ANFIS112.5241.274643.709.012501.924562.43598.250.0212Low

The functioning temperature of the fuel stack (343 K)
EIC-FLC112.3541.524664.778.96501.904585.9398.310.025High
IHC-FLC112.4841.544672.418.99501.984595.3198.350.018High
AB-FLC113.0841.504692.829.08502.214616.3298.370.0157Medium
EDE-FLC113.0942.234775.799.09502.244700.3398.420.015Medium
MPO-FLC113.1042.334787.529.18502.254718.10098.550.012Low
AGA-ANFIS113.1142.344789.079.24503.214720.5898.570.010Low