The Multiobjective Control Based on Tolerance Optimization in a Multienergy System
Table 4
Description of simulation parameters.
| Parameter | Value |
| Reference capacity (MW) | 10 | Line nominal voltage (kV) | 12.66 | Voltage upper and lower limit range (%) | ±10 | Maximum current of the line (A) | 456 | Charging and discharging efficiency (%) | 95 and 92 | Upper and lower limits of SOE (%) | 90 and 10 | Initial SOE value (%) | 50 | Rated power of energy storage system (MW) | 3.3 | Rated capacity of energy storage system (MWh) | 13.2 | Cost per kWh of energy storage system (¥/kWh) | 0.574 | Rated power of distributed power sources (MVA) | 10 | Distributed power generation cost coefficient (¥/kWh) | 40000 | Distributed power generation cost coefficient (¥/kWh) | 650 | Distributed power generation cost coefficient (¥) | 8 | Photovoltaic installed capacity of node #6 (MW) | 4 | Photovoltaic installed capacity of node #6 (MW) | 2 | Cost of photovoltaic kWh at nodes #6 and #13 (¥/kWh) | 0.293 | Wind power installed capacity at node #22 (MW) | 3 | #32 node wind power installed capacity (MW) | 2 | Wind power cost per kilowatt hour at nodes #22 and #32 | 0.3 |
|
|