No.Mass flow rate of propane-butane mixture (kg/h)Mass air flow rate (kg/h)αφCO (ppm)NOx (ppm)Tос (°С)О2 (%) (kW/m3)ReQ (kW)

10.3587.811.560.64157522.530.416.2100.65809.193.98
20.3588.211.640.61132125.531.116100.66093.683.98
30.3588.591.710.58114028.032.516.2100.66363.943.98
40.3588.961.780.56107030.032.716.5100.66627.093.98
50.3589.311.850.54104431.334.116.6100.66876.013.98
60.3589.651.920.52103031.93416.6100.67117.833.98
70.4388.211.340.75978.3243314.1123.26150.584.87
80.4388.591.400.71714.724.73414.2123.26420.844.87
90.4388.961.460.68620.025.33414.1123.26683.994.87
100.4389.311.510.66540.025.932.513.8123.26932.914.87
110.4389.651.570.64477.327.02613.6123.27174.724.87
120.4389.981.620.62420.028.72913.8123.27409.424.87
130.43810.291.670.60380.032.33313.8123.27629.904.87
140.5069.651.360.74519.527.035.913.1142.37223.095.62
150.5069.981.410.71410.127.836.113.1142.37457.795.62
160.50610.291.450.69336.533.936.514.1142.37678.265.62