Research Article

Comparative Analysis of Swirl Burner and Cross Jet Burner in Terms of Efficiency and Environmental Performance

Table 3

Flue gas sampling results for a gas burner with transverse jet mixing.

No.Mass flow rate of propane-butane mixture (kg/h)Mass air flow rate (kg/h)αφCO (ppm)NOx (ppm)Tос (°С)О2 (%), (kW/m3)ReQ (kW)

10.3583.10.621.6127.4545.522.712.5100.61728.514.02
20.3583.580.711.4125.0060.022.315.6100.61968.444.02
30.3584.010.801.2524.0065.022.315.3100.62183.384.02
40.3584.390.871.1523.1866.122.315.7100.62373.324.02
50.3584.740.941.0622.4266.522.415.5100.62548.274.02
60.4383.10.502.00170.83921.413.2123.21768.504.92
70.4383.580.581.7271.0545.221.713.4123.22008.434.92
80.4384.010.651.5440.0848.221.813.5123.22223.374.92
90.4384.390.711.4130.0049.822.213.5123.22413.314.92
100.4384.740.771.3026.0050.922.313.2123.22588.264.92
110.4385.070.821.2224.0051.522.213.9123.22753.214.92
120.4387.391.200.8317.0052.323.713.0123.23912.884.92
130.4388.211.340.7515.0053.023.613.9123.24322.774.92
140.4388.961.460.6813.0054.923.614.4123.24697.664.92
150.5063.580.502.00177.139.222.312.3142.32042.425.69
160.5064.010.561.7967.1943.822.612.3142.32257.365.69
170.5064.390.621.6140.0045.022.512.4142.32447.305.69
180.5064.740.671.4927.4545.422.712.5142.32622.255.69
190.5065.070.711.4121.1245.522.313.2142.32787.215.69
200.5065.380.761.3218.0045.522.712.5142.32942.165.69