Research Article
Simulation of the Compression Testing of Additively Manufactured Lattice Structures Using Inputs from Microcomputed Tomography
Figure 6
Stress-strain plots of final models for P280-T30 (a), P280-T60 (b), P280-T90 (c), P210-T30 (d), and P360-T30 (e) compared with the as-designed model and experimental results with upper and lower bounds showing the one standard deviation from the mean.
(a) |
(b) |
(c) |
(d) |
(e) |