Research Article
Time-Series Forecasting of a Typical PWR Undergoing Large Break LOCA
Table 1
General system parameters and initial conditions.
| Parameters | DCD |
| Power (MWt) | 3,983 | Power peaking factor | 2.258 | RCP flowrate (kg/s) | 5250.0 | Core flowrate (kg/s) | 20361.0 | Primary pressure (MPa) | 15.51 | Feedwater temperature (K) | 505.23 | Safety injection tank coolant volume (m3) | 52.63 | Safety injection tank gas pressure (MPa) | 4.25 | Safety injection tank coolant temperature (K) | 302.5 | IRWST temperature (K) | 302.5 | Core inlet temperature (K) | 563.8 | Core outlet temperature (K) | 597.1 | Upper head temperature (K) | 584.5 | Pressurizer level (m) | 8.18 | Secondary pressure (MPa) | 6.86 |
|
|