Journals
Publish with us
Publishing partnerships
About us
Blog
Contrast Media & Molecular Imaging
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Contrast Media & Molecular Imaging
/
2021
/
Article
/
Tab 4
/
Review Article
Diagnostic Accuracy of 18F-FDG-PET/CT and MRI in Predicting the Tumor Response in Locally Advanced Cervical Carcinoma Treated by Chemoradiotherapy: A Meta-Analysis
Table 4
Diagnostic performance of MRI and PET/CT in patients with LACC post-CRT.
Parameter
PET/CT
MRI
Sensitivity (95% CI)
0.835 (CI 95% 0.799–0.866)
0.827 (CI 95% 0.75–0.88)
Specificity (95% CI)
0.778 (CI 95% 0.744–0.811)
0.684 (CI 95% 0.620–0.744)
PLR (95% CI)
4.135 (CI 95% 2.164–7.899)
2.920 (CI 95% 1.980–4.305)
NLR (95% CI)
0.215 (CI 95% 0.116–0.398)
0.226 (CI 95% 0.106–0.482)
DOR (95% CI)
25.216 (CI 95% 8.270–76.887)
15.140 (CI 95% 5.507–41.626)
PPV
75%
85%
NPV
62%
86%
Accuracy
80%
74%
AUC-SROC
0.8007
0.9081
I
2
65%
82%
Q
index
0.7384
0.8379