Research Article

Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA

Table 3

Comparison as a whole.

Experimental groupControl groupT/Z

Aortic root (HU)523 ± 82634 ± 87−11.650.001
SD noise (HU)28 ± 432 ± 5−6.17a0.001
Contrast tissue (HU)123 ± 12125 ± 15−1.500.136
SNR18.7 ± 3.520.3 ± 4.0−3.220.001
CNR14.3 ± 3.316.3 ± 3.7−4.430.001
Proximal RCA (HU)473 ± 90642 ± 101−16.530.001
Mid RCA (HU)440 ± 98612 ± 103−15.090.001
Distal RCA (HU)390 ± 94581 ± 117−15.330.001
Proximal LAD (HU)491 ± 84598 ± 93−10.250.001
Mid LAD (HU)440 ± 86556 ± 93−10.790.001
Distal LAD (HU)363 ± 75482 ± 94−8.58a0.001
Proximal LCX (HU)478 ± 83585 ± 96−7.86a0.001
Distal LCX (HU)372 ± 80485 ± 94−11.070.001

a: Calculated using the Wilcoxon rank-sum test.