Microtensile Bond Strength of Etch-and-Rinse Adhesives in Different Hydroabrasion Conditionings

Table 2

Descriptive statistics for microtensile strength of different groups with different dentin treatment.

AdhesiveTreatment
ControlHA/3HA/5HA/7
Mean ± SDNormality testMean ± SDNormality testMean ± SDNormality testMean ± SDNormality test

EXC (n = 120)27.7 ± 10.80.10027.9 ± 6.30.01528.5 ± 7.90.00330.6 ± 11.90.014
ENA (n = 120)32.5 ± 6.40.01530.7 ± 6.40.02831.1 ± 6.60.45132.9 ± 7.40.001
UNI (n = 120)33.9 ± 4.90.14134.2 ± 4.90.08035.1 ± 5.90.01234.8 ± 6.20.021

Mean ± standard deviation in MPa. value from the Shapiro–Wilk normality test. HA/3, hydroabrasion conditioning with an air pressure of 3 bar and a minimum aluminium oxide particle flow; HA/5, hydroabrasion conditioning with an air pressure of 5 bar and a medium aluminium oxide particle flow; HA/7, hydroabrasion conditioning with an air pressure of 7 bar and a maximum aluminium oxide particle flow; EXC, ExciTE DSC, Ivoclar Vivadent AG, Schaan/Liechtenstein; ENA, ENA Bond, Micerium, Genova, Italy; UNI, Scotchbond Universal, 3M Oral Care, Seefeld, Germany.