Research Article

Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures

Table 2

Mean microstrain of abutment teeth and dental mini-implants under applied unilateral loading (mean strain values (±SD in microstrain)).

GroupLoaded siteUnloaded site
ImplantAbutment toothImplantAbutment tooth
150 N200 N150 N200 N150 N200 N150 N200 N

110.50 (6.83)b19.04 (9.27)c10.07 (9.89)a7.23 (12.30)a
2−170.65 (6.03)a−202.32 (4.29)a−2.48 (10.22)a2.11 (12.12)a14.48 (7.85)b22.57 (5.09)b0.21 (12.62)a6.01 (7.56)a
3−177.59 (11.61)a−186.22 (12.37)b9.78 (9.02)ab14.29 (8.42)bc−6.39 (14.81)a4.07 (8.58)a1.97 (15.93)a2.11 (10.63)a
4−99.12 (3.70)b−113.84 (6.38)c9.09 (4.29)ab5.04 (6.45)ab−10.85 (6.64)a−0.06 (5.83)a9.58 (10.95)a2.82 (7.20)a

Comparisons done appear in the same column. The same upper superscript case letter in the same column indicates no significant difference at  = 0.05.