Research Article

Effect of Number and Location on Stress Distribution of Mini Dental Implant-Assisted Mandibular Kennedy Class I Removable Partial Denture: Three-Dimensional Finite Element Analysis

Table 2

Material properties of finite element models [3438].

MaterialYoung’s modulus (MPa)Poisson’s ratio

Tooth dentin186000.31
Bone4042.50.30
Acrylic resin22000.31
Cobalt chromium metal2110000.30
Titanium dental implant1100000.33
Periodontium68.900.45
Connective tissue0.680.45
Stainless steel190000.31
Rubber cap50.45