Research Article

Effect of Different Post Materials and Adaptability on Fracture Resistance and Fracture Mode in Human Endodontically Treated Teeth

Table 2

Mean and standard deviation of fracture resistance values (N) of study groups.

Study groupsNMean (N)/SDMin, max

C10585.9 ± 28.1a554.9, 628.1
CF10649.5 ± 44.2bc593.2, 708.1
PDT10616.2 ± 39.9ab561.3, 677.5
ADT10679.8 ± 57.8c612.1, 778.5
PHR10607.2 ± 32.4ab572.8, 653.2
AHR10688.4 ± 56.4c608.4, 751.3

Same superscript indicated no statistically significant difference, analyzed by one-way ANOVA and tukey HSD post-hoc test ().