Research Article

The Effect of Different Obturation Techniques in Primary Teeth on the Apical Microleakage using Endoflas: A Comparative In Vitro Study

Table 1

Descriptive statistics of dye leakage in several experimental groups.

Mean±SD±SEMinimumMaximum

GI0.0540.0250.0070.0190.102
GII0.1330.0910.0260.0440.277
GIII0.1460.0660.0190.0470.230

Group I: endodontic pressure syringe; group II: modified disposable syringe; group III: reamer; SD, standard deviation; SE, standard error.