Research Article
Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
Table 7
Tukey’s test of multiple comparisons for different groups of wettability contact angle test.
| Tukey’s HSD test | Groups pairs | Difference | Standard error | Q score | P-value | Sig. |
| C1 vs. C2 | 2.81 | 1.9995 | 1.4053 | 0.85506 | NS | C1 vs. P3 | 15.318 | 1.9995 | 7.6608 | 0.00023 | S | C1 vs. P5 | 9.942 | 1.9995 | 4.9721 | 0.01648 | S | C1 vs. P7 | 3.962 | 1.9995 | 1.9815 | 0.63401 | NS | C2 vs. P3 | 12.508 | 1.9995 | 6.2555 | 0.00217 | S | C2 vs. P5 | 7.132 | 1.9995 | 3.5668 | 0.1252 | NS | C2 vs. P7 | 1.152 | 1.9995 | 0.5761 | 0.99374 | NS | P3 vs. P5 | 5.376 | 1.9995 | 2.6886 | 0.34858 | NS | P3 vs. P7 | 11.356 | 1.9995 | 5.6793 | 0.00544 | S | P5 vs. P7 | 5.98 | 1.9995 | 2.9907 | 0.2526 | NS |
|
|