Research Article

The Effects of Bone Cement Volume in Percutaneous Vertebroplasty for Thoracolumbar Junction Vertebral Compression Fractures: A Clinical Comparative Study

Table 3

The IDL, STVF, and SAVF in respective groups with different volumes of cement.

≤5 mL>5 mLRR value

IDL13/14622/1701.450.250
STVF4/14614/1703.010.036
SAVF2/14610/1704.290.029

IDL: intervertebral disc leakage; STVF: subsequent total vertebral fracture; SAVF: subsequent adjacent vertebral fracture; RR: relative risk.